PhysioGo 500I

PhysioGo 500I device used for electrotherapy, laser therapy and magnetotherapy

Contact Us
More Products

PhysioGo 500I Device For electrotherapy, Magnetotherapy and Laser Therapy

Advanced two-channel electrotherapy, laser therapy and magnetotherapy device, PhysioGo 500I . Up to 285 treatment programs are available, including Voll and Nogier acupuncture programs and 38 electrotherapy sequences. The device's ergonomics are influenced by the Favorites option - a function that offers quick access to a list of the most frequently selected programs, the user can also set up to 300 of their own programs.

What makes the PhysioGo 500I stand out?

  • 7" color display with touch panel
  • Two independent treatment channels
  • Adjusting the intensity in the patient circuit simultaneously for both channels or separately
  • Electrode test
  • Manual mode
  • Disease entities selected by name or field
  • Database of built-in treatment programs
  • Database of built-in treatment sequences
  • User program database
  • User Sequence Database
  • Favorite programs
  • Ability to edit program names and user sequences
  • Encyclopedia with description of the treatment methodology
  • Statistics of performed procedures
  • Adjusting the volume of the buzzer

Technical Parameters

Controller - Max. Current Intensity in Patient Circuit (CC mode) galvanic: 40 mA
diadynamic, pulsed: 60 mA
interferential, Kotz, unipolar undulating: 60 mA
TENS: 140 mA
tonolysis: 100 mA
microcurrents: 1000 μA
Max. Voltage Amplitude in Patient Circuit (CV mode) 140V
Treatment Clock - Electrotherapy 30 sec - 60 minutes
Laser Device Class 3B
Treatment Clock - Laser Therapy 1 sec - 100 minutes
Maximum Magnetic Field Induction 10 mT
Working Frequency 2-120Hz
Intermittent Mode Parameters pulse 1 s / break 0.5 – 8 s
Treatment Clock - Magnetotherapy 30 sec – 30 minutes
Dimensions 34x28x11-16
Mass 6kg
Battery Type (Option) Li-ion
Battery Capacity (Option) 2250mAh
Power Supply, Power Consumption 230V, 50/60Hz, 75W, 90VA

Standard equipment

  • camera training
  • power cord
  • patient cables 2 pcs.
  • electrotherapy electrodes - 6 x 6 cm 4 pcs.; 7.5 x 9 cm 2 pcs.
  • viscose covers for electrodes – 6 x 6 cm 8 pcs.; 7.5 x 9 cm 4 pcs.
  • Velcro straps 40 x 9 cm 2 pcs; 100 x 9 cm 2 pcs or 40 x 10 cm 2 pcs; 100 x 10 cm 2 pcs.
  • laser therapy warning labels
  • DOOR door lock plug
  • capacitive stylus for LCD screen
  • LCD screen cloth
  • masking covers with cut-out 2 pcs.
  • full masking covers 2 pcs.
  • spare fuses WTA-T 1 A/250 V 2 pcs
  • user manual
  • post-inspection report on safety tests.
  • technical passport
  • Warranty Card

Optional equipment

  • self-adhesive electrodes 5 x 5 cm , 5 x 10 cm
  • point electrodes with adapter 6 mm , 10 mm , 15 mm , 20 mm
  • sand bag 21 x 14 cm , 21 x 28 cm
  • R 660 nm/ 80 mW point probe with holder
  • IR point probe 808 nm/ 400 mW with holder
  • R+IR 100 mW + 450 mW scanning applicator with stand
  • CL 1800 R 5 x 40 mW and IP 4 x 400 mW shower applicator with handle
  • Shower applicator stand
  • Straight optical fiber Ø 6 mm
  • 45° angled fiber optic cable Ø 6 mm
  • 45° angled fiber optic Ø 6 mm tapered for laser puncture
  • Protective glasses for laser therapy
  • CPE1 and CPE2 magnetic field flat applicators with covers
  • Permanent magnet
  • PRO bag
  • Versa / Versa X table

Electrotherapy - indications

  • Chronic or acute spinal pain conditions
  • Various types of discopathy
  • Neuralgia
  • Osteoarthritis
  • Rheumatic diseases
  • Muscular dystrophies
  • Conditions after injuries to the musculoskeletal system, such as fractures, contusions and sprains
  • Soft tissue inflammation
  • Sciatica
  • Headaches, including migraine headaches

Electrotherapy - contraindications

  • Implanted pacemaker
  • Implants or metal parts
  • Cancers
  • Thrombosis
  • Embolism
  • Sensory disorders
  • Pregnancy (treatment in the abdominal or lower spine area)
  • General infections with high fever
  • Inflammation of the skin, especially in the places where electrodes are applied

Electrotherapy - treatment

Electrotherapy - treatment

Electrotherapy - treatment

Electrotherapy - treatment

Laser therapy - biological influence

  • Increase in ATP levels
  • Stimulation of protein synthesis, including collagen
  • Changes in the structure and functions of biological membranes
  • Increased activity of certain enzymes and prostaglandins
  • Modulation of immune processes
  • Phagocytosis effect
  • Increased cell mobility and reproduction

Laser therapy - indications

  • Post-operative wounds and scars
  • Ulcers and scars after transplantation
  • Various diseases of the musculoskeletal system
  • Skin diseases
  • Rheumatism and inflammation
  • Wound and ulcer therapy

Laser therapy - contraindications

  • Cancer within 5 years of recovery
  • Pregnancy
  • Presence of electronic implants
  • Acute bacterial, viral, and fungal infections
  • Fever and general weakness of the body
  • Epilepsy
  • Light allergy
  • Overactivity of endocrine glands
  • Unstable diabetes
  • Skin lesions of unspecified origin

Laser therapy - treatment

Laser therapy - treatment

Laser therapy - treatment

Laser therapy - treatment

Magnetotherapy - biological influence

  • Accelerates ion exchange
  • Improves peripheral blood circulation
  • Increases the supply of oxygen to tissues and increases its partial pressure
  • Acceleration of the soft tissue regeneration process
  • Increased DNA content
  • Increased protein absorption

Magnetotherapy - in indications

  • Delayed bone union
  • Pseudopontan
  • Osteoporosis
  • Osteoarthritis
  • Rheumatoid arthritis
  • Ulcers and trophic changes of the lower legs
  • Bacterial infections of the skin and soft tissue
  • Keloids
  • Condition after stroke
  • Migraine and vasomotor headaches
  • Cranial and peripheral nerve dysfunction
  • Multiple sclerosis
  • Infectious diseases of the cornea
  • Optic Nerve Atrophy
  • Hypertension
  • Ischemic heart disease
  • Heart arrhythmia
  • Irritable bowel syndrome
  • Chronic pancreatitis

Magnetotherapy - in indications

  • Pregnancy
  • Cancer
  • Active tuberculosis
  • Juvenile diabetes
  • Thyrotoxicosis
  • Gastrointestinal bleeding
  • Severe infections
  • Presence of electronic implants (e.g., pacemaker)

Magnetotherapy - treatment

Magnetotherapy - treatment

Magnetotherapy - treatment

Magnetotherapy - treatment